Multi Conductor Shielded Data Cables CM CL3 PVC Insulation Conductor: bunched strand annealed tinned copper Insulation: PVC insulation color coded Shield: Overall aluminum/polyester shield stranded tinned copper drain wire Jacket: PVC jacket temperature range -20 to +60C Packaging: Spools or reels REELEX boxes Application: SIGNALING/ELECTRONIC /RS 232 APPLICATIONS/CONTROL CIRCUITS
Part No. |
No. of corns |
AWG size |
Conr. Strand& coating |
Nominal insulation thickness |
Nominal jacket thickness |
Nominal outer diameter |
Nominal capaci tance |
Weight LBS/1000FT |
Inches |
mm |
Inches |
mm |
Inches |
mm |
DZ330660 |
1pair |
16 |
19/29tinned |
.015 |
.38 |
.020 |
.51 |
.230 |
5.84 |
60 |
25 |
DZ330661 |
3 |
16 |
19/29tinned |
.015 |
.38 |
.020 |
.51 |
.245 |
6.22 |
45 |
48 |
Nylon rip cord under jacket Drain wire: 18 AWG 7/26 tinned copper
Part No. |
No. of corns |
AWG size |
Conr. Strand& coating |
Nominal insulation thickness |
Nominal jacket thickness |
Nominal outer diameter |
Nominal capaci tance |
Weight LBS/1000FT |
Inches |
mm |
Inches |
mm |
Inches |
mm |
DZ330670 |
1pair |
14 |
19/27tinned |
.015 |
.38 |
.020 |
.51 |
.255 |
6.48 |
65 |
49 |
DZ330671 |
3 |
14 |
19/27tinned |
.015 |
.38 |
.020 |
.51 |
.275 |
6.99 |
45 |
65 |
Nylon rip cord under jacket +CL3 only. UL defines Type CM as 26 to 16 AWG Drain wire Size: 16 AWG 19/29 tinned copper. Capacitance:(pf/ft) * Mutual (condctor to conductor) ** One conductor to the others connected to shield Standard Spool or Reel Size: 1000ft Standard Jacket Color: Gray Color Code:Black, red, white. |